RE 2521-BLN
Low pressure grade RO element for brackish water
SPECIFICATIONS
General Features:
- Permeate flow rate: 300 GPD ( 1.1 m3/day)
- Stabilized salt rejection: 99.2%
- Effective membrane area: 12 ft2 (1.1 m2)
- Membrane type: Thin-Film Composite
- Membrane material: Polyamide(PA)
- Element configuration: Spiral-Wound, FRP Wrapping
APPLICATION DATA
Operating Limits:
- Max. Pressure Drop / Element - 15 psi (0.1 MPa)
- Max. Pressure Drop / 240” Vessel - 60 psi (0.41 Mpa)
- Max. Operating Pressure - 600 psi (4.14 MPa)
- Max. Feed Flow Rate - 6 gpm (1.36 m3/hr)
- Min. Concentrate Flow Rate - 1 gpm (0.23 m3/hr)
- Max. Operating Temperature - 113 oF (45 oC)
- Operating pH Range - 2.0–11.0
- CIP pH Range 1.0–13.0
- Max. Turbidity - 1.0 NTU
- Max. SDI (15 min) - 5.0
- Max. Chlorine Concentration < 0.1 mg/L
Design Guidelines for VariousWater Sources:
- Wastewater Conventional (SDI < 5) - 8–12 gfd
- Wastewater Pretreated by UF/MF (SDI < 3) - 10–14 gfd
- Seawater, Open Intake (SDI < 5) - 7–10 gfd
- Seawater, Beach Well (SDI < 3) - 8–12 gfd
- Surface Water (SDI < 5) - 12–16 gfd
- Surface Water (SDI < 3) - 13–17 gfd
- Well water (SDI < 3) - 13–17 gfd
- RO permeate (SDI < 1) - 21–30 gfd
Saturation Limits (Using Antiscalants) *:
- Langlier Saturation Index (LSI) <+1.5
- Stiff and Davis Saturation Index (SDSI) <+0.5
- CaSO 4 - 230% saturation
- SrSO4 - 800% saturation
- BaSO4 - 6,000% saturation
- SiO2 - 100% saturation
*The above saturation limits are typically accepted by proprietary antiscalant manufacturers. It is the user’s responsibility to ensure proper chemical(s) and
concentration are dosed ahead of the membrane system to prevent scale
formation anywhere within the membrane system. Membrane elements fouled or damaged due to scale formation are not covered by the limited warranty.
Rakendusandmed
Tööpiirangud:
- Maks. rõhukadu elemendi kohta – 15 psi (0,1 MPa)
- Maks. rõhukadu 240’’ anumal – 60 psi (0,41 MPa)
- Maks. töörõhk – 600 psi (4,14 MPa)
- Maks. sööteveevool – 6 gpm (1,36 m³/h)
- Min. kontsentraadi vool – 1 gpm (0,23 m³/h)
- Maks. töötemperatuur – 113 °F (45 °C)
- Töö pH vahemik – 2,0–11,0
- CIP pH vahemik – 1,0–13,0
- Maks. hägusus – 1,0 NTU
- Maks. SDI (15 min) – 5,0
- Maks. kloori kontsentratsioon – < 0,1 mg/L
Projekteerimisjuhised eri veetüüpidele:
- Reovee tavapärane eeltöötlus (SDI < 5) – 8–12 gfd
- Reovesi, töödeldud UF/MF-ga (SDI < 3) – 10–14 gfd
- Merevesi, avatud veehaare (SDI < 5) – 7–10 gfd
- Merevesi, rannakaev (SDI < 3) – 8–12 gfd
- Pinnavesi (SDI < 5) – 12–16 gfd
- Pinnavesi (SDI < 3) – 13–17 gfd
- Puurkaevuvesi (SDI < 3) – 13–17 gfd
- RO permeaat (SDI < 1) – 21–30 gfd
Küllastuspiirid (kasutades antiskalante):*
- Langelier'i küllastusindeks (LSI) < +1,5
- Stiff ja Davis küllastusindeks (SDSI) < +0,5
- CaSO₄ – 230 % küllastus
- SrSO₄ – 800 % küllastus
- BaSO₄ – 6000 % küllastus
- SiO₂ – 100 % küllastus
* Need küllastuspiirid on üldiselt aktsepteeritud antiskalandi tootjate poolt.
Kasutaja vastutab sobivate kemikaalide ja nende kontsentratsioonide doseerimise eest enne membraanisüsteemi, et vältida katlakivi ja setete teket süsteemis.
Membraanielemendid, mis on kahjustatud või ummistunud katlakivi tõttu, ei kuulu garantiisse.
| Width (cm) |
Height (cm) |
Length (cm) |
Weight (kg) |
| 9 |
9 |
58 |
3 |
By clicking the following link, you can view and download:
CSM reverse osmosis membrane RE2521-BLN (300GPD)_data sheet